A protein–protein docking search has a practical trade-off: exploring every possible orientation can take time, while narrowing the search too aggressively can exclude plausible poses. This is a common problem when you have some idea where proteins may interact, but not enough information to specify a single binding orientation.
Hex, available as a SAMSON Extension, offers a way to manage that trade-off: define a starting arrangement, then restrict the angular region explored during docking. The key is to use constraints as a way to focus a justified search—not as a substitute for evidence about the binding site.
Start with structures you can trust
Before docking, prepare both proteins. Remove alternate-location atoms and, where appropriate, waters, monatomic ions, and ligands. Add hydrogens if they are absent, but do not overwrite hydrogens that already reflect a chosen protonation state. If residues or heavy atoms are missing, the PDBFixer Extension can help repair the structure. Preparation matters because docking results depend on the structures supplied to the search.
In SAMSON, load the sample or your own structures, open Hex, and assign one protein as the receptor and the other as the ligand. Save the ligand’s initial conformation before running a search. That gives you a convenient way to return to the starting arrangement if you want to test different parameters.

Use orientation constraints only when they are justified
Hex can search across the full sphere or a narrower angular range. In the Range angles sampling method, the receptor and ligand range angles define spherical cones around the intermolecular axis. A range of 180 degrees applies no angular constraint. A smaller value focuses the search around the starting orientation.
If you have a credible idea of the interface, first move and orient the ligand near the putative binding site. Then set the receptor and ligand range angles in Advanced parameters. The tutorial uses 45 degrees for each as an example of a loose constraint. This is not a universal setting: it is useful only when the starting arrangement is meaningful. If the interface is unknown, a narrow cone could simply prevent the search from finding a relevant orientation.
Remember that Hex rotates and positions the ligand around the receptor. Range angles are therefore tied to the starting arrangement and the intermolecular axis—not a way to tell Hex exactly which residues must bind. You can also limit the ligand’s twist around that axis.

Choose a search that fits the structures
Hex separates a coarse Steric scan from the higher-resolution Final search. The coarse pass discards many orientations before the finer search, which can reduce the work required. The documentation suggests a Steric scan order of 16–18 in many cases, with combinations such as 16 followed by 25, or 20 followed by 30. The final order should be higher than the steric-scan order when the scan is enabled.
For the Final search, the default order of 25 is often sufficient. The documentation recommends considering 30 for high-resolution crystal structures when binding-related conformational changes are expected to be small, and 25 for model-built or more flexible structures. These are starting points, not guarantees. If you change the search domain or resolution, record those choices so you can interpret and reproduce the results.
Correlation type also matters. Shape-only searches are available, as are options that include electrostatics. Electrostatics may help when the proteins have complementary formal charges; the documentation advises against using electrostatics when docking DNA or RNA.
Read poses as candidates, not answers
After docking, inspect the Results tab. Hex clusters modes and lets you view the best mode per cluster or all modes. Selecting a row restores that ligand conformation, and you can create a conformation in the document for further examination. Use visual models, distance measurements, and interaction-analysis tools to assess candidate poses. For example, SAMSON’s Protein-Ligand Interaction Analyzer can compute contact area and hydrogen bonds, while the Hydrogen Bond Finder can visualize hydrogen bonds between molecules.
A top-ranked pose is a candidate for further analysis, not proof of a biological interaction. Look across clusters, check for steric clashes and plausible contacts, and consider whether the pose is consistent with what you know about the system. If you are uncertain about the binding site, compare broader and more focused searches rather than treating a single constrained run as definitive.
For the full workflow and parameter details, read the original Hex protein-docking tutorial.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.
