A protein-docking run can produce many plausible-looking poses—and take longer than necessary—when the search explores orientations that are nowhere near a suspected binding site. If you already have a reasonable idea of where the proteins interact, you can use that knowledge to narrow the search in Hex through SAMSON. The key is to treat the constraint as a way to focus the calculation, not as proof that the binding site or starting orientation is correct.
Hex searches protein orientations around an intermolecular axis connecting the receptor and ligand. With the default range angles of 180 degrees, the full sphere is available to the search. Reducing a range angle limits the orientations sampled to a cone around that axis. This can reduce the search domain and computation time, while also reducing the number of poses that are irrelevant to the site you want to investigate.
Prepare before constraining
Begin with clean receptor and ligand structures. The tutorial recommends removing atoms with alternate locations, removing water, monatomic ions, and ligands when present, and adding hydrogens if they are missing. If a structure has missing residues or heavy atoms, the PDBFixer extension can help address those issues. Be careful with hydrogens that were already added using a particular protonation choice: the tutorial advises not modifying them.
In SAMSON, open the Hex app, set one protein as the receptor and the other as the ligand, and save the ligand’s initial conformation if you may want to repeat the calculation with different settings. The sample tutorial uses proteins 2PTC_E and 2PTC_I, but you can load your own structures.
Use range angles to focus the search
Set the Sampling method to Range angles, then open Advanced parameters. If the likely interface residues are known, orient the ligand toward the receptor and set the receptor and ligand range angles to limit the search around that starting orientation. The tutorial demonstrates 45 degrees for each protein as an example—not a universal setting. A range angle of 180 degrees imposes no angular constraint; a smaller value narrows the orientations considered.

The cones help make the constraint visible: their apexes are at the protein centers, and their axes follow the intermolecular direction. You can also restrict the ligand’s twist rotation about that axis. To position or orient the ligand before applying constraints, use a SAMSON Move editor.
A practical safeguard: narrow constraints are only useful when the starting orientation is credible. If the ligand is pointed away from the actual interface, a restricted search may simply exclude relevant poses. When the site is uncertain, keep the search broader, or compare constrained and less-constrained runs rather than treating one result as definitive.
Balance speed and search detail
Hex can first perform a lower-resolution Steric scan, then refine the promising orientations in the higher-resolution Final search. The documentation reports that a Steric scan order of 16–18 is sufficient in most cases and gives examples of 16 for the scan with 25 for the final search, or 20 with 30. The final-search order is generally higher than the steric-scan order. A value of 25 is usually sufficient; 30 is recommended for high-resolution crystal structures when binding-related conformational changes are expected to be small. Model-built or more flexible structures may be better suited to 25.
After the run, inspect the clustered results rather than relying only on the top-ranked pose. Selecting a row restores that ligand conformation; you can create a conformation in the document from a result row and then examine it with visual models or interaction-analysis tools. This makes it easier to assess whether a promising score also corresponds to a pose that is sensible for the system.

For the complete workflow and parameter details, see the Protein docking with Hex tutorial.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON at samson-connect.net.