A structure can look ready for molecular dynamics and still contain details that complicate preparation: alternate locations, waters you do not want, small molecules you are not simulating, or ions that should be handled later. Cleaning these up can make the next steps clearer—but removing everything that is not protein can also discard molecules that matter to the system.
The useful distinction is not simply “keep” or “delete.” It is: what do I intend to simulate, and what will the preparation workflow need? Here is a careful way to think through that decision before moving on to GROMACS preparation.
Start with a deliberate cleanup
In SAMSON, load your structure and open Home > Prepare. The tutorial uses the 1AKI protein structure as an example; you can fetch it through Home > Fetch by entering 1AKI in the PDB or PDB (mmCIF) field.

During preprocessing, consider removing alternate locations, unnecessary small molecules, water you do not need, and monatomic ions. Adding hydrogens at this point is optional: GROMACS can add them as well. The key is to treat each removal option as a choice about your model, not as a box to check automatically.
Pause before removing ligands or cofactors
A ligand or cofactor may be central to the system you want to study. If you intend to simulate it, do not remove it during cleanup. If you want to keep an arbitrary molecule, you will need a topology file (.itp) for it. The documentation points to external tools such as the ATB Server or CGenFF for generating such files; they can be provided later during the Preparation step.
If a small molecule is not needed, you can remove it using the preparation options or select small molecules through Select > Biology > Ligands. Check the selection before erasing it. This is especially worthwhile when the system includes cofactors or other molecules for which GROMACS cannot generate a topology and that are not part of your intended simulation.
Water is not always just water
Removing all water is not suitable for every system. Some waters may be tightly bound or function in an active site, so a blanket removal could discard molecules you intended to preserve. If those waters matter, select the active-site structure, residue, or atoms first. Then right-click the selection and choose Expand selection > Advanced. Set the node type to Water, choose waters beyond a distance from the selection, and use auto-update to inspect what will be selected. Verify the selection before choosing Erase selection.

This targeted approach makes the decision visible: preserve the waters near the selected active site and remove only those beyond the chosen distance. It does not decide which waters are biologically important for you, so review the resulting selection before deleting anything.
Use cleanup as a checkpoint
Before continuing, ask yourself three questions: Have I kept every ligand or cofactor I plan to simulate? Have I removed only the waters I actually want to remove? Are the remaining arbitrary molecules supported by the topology files needed later? A quick review here can prevent avoidable confusion in the subsequent preparation workflow.
Once the structure contains the molecules you intend to model, continue to the Preparation step to define the simulation model, box, solvent, ions, and project files. For the full walkthrough, see the GROMACS Wizard system preprocessing documentation.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.