A molecular structure can look ready for simulation while still containing details that complicate preparation: alternate atom locations, waters you do not need, small molecules without available topology files, or ions that you do not intend to model. Removing everything that looks unfamiliar is not the answer, though. A ligand or a tightly bound water molecule may be important to the system you want to study.
A useful pre-simulation cleanup is therefore less about making a structure look simple and more about making deliberate choices. Here is a practical way to think through that step in SAMSON’s GROMACS Wizard, using the 1AKI structure as an example.
Start with a structure you can inspect
Load 1AKI through Home > Fetch by entering 1AKI in the PDB or PDB (mmCIF) field and clicking the matching Load button. You can also open a structure already saved on your computer using Home > Open. Import settings can be left at their defaults for this walkthrough.
Before deleting anything, decide which components are part of the model you intend to simulate. In particular, identify ligands or cofactors you want to keep. That decision matters: a molecule you retain may need its own topology file later, while one you do not need can be removed during cleanup.

Clean up with a checklist, not a blanket rule
Open Home > Prepare and consider the cleanup options in turn:
- Remove alternate locations. Structures can contain alternative positions for atoms. Removing alternate locations helps avoid carrying those alternatives into the preparation workflow.
- Remove ligands. Use this option for small molecules you do not intend to simulate. Do not remove a ligand or cofactor that is part of the system you want to study.
- Remove water. This may be suitable when existing waters are not needed, but it is not a universal choice. Some crystal waters are tightly bound or functional, including waters near an active site.
- Remove monatomic ions. Remove ions that are not needed in the model at this stage.
- Add hydrogens. This option is optional here; GROMACS can add hydrogens during its workflow as well.
The goal is a starting structure containing the molecules you mean to carry forward—not simply the fewest possible molecules. When uncertain about a component, pause and check whether it is relevant to your intended simulation before erasing it.
Keep useful waters; remove distant ones selectively
If you want to preserve waters near a ligand or active site while removing waters farther away, you can select by distance instead of removing all water. First select the relevant structures, residues, or atoms—for example, the ligand or active-site atoms. Then right-click the selection in the Document view or Viewport and choose Expand selection > Advanced.
In the dialog, set the node type to Water and choose beyond a distance from the selected active-site region. The auto-update option can help you preview the selection. Check which waters are selected before confirming; then right-click the verified selection and choose Erase selection. This gives you a chance to preserve nearby waters that may be functional while removing waters outside the region you care about.

Plan ahead for molecules you keep
Keeping an arbitrary molecule in the system may require a topology file, such as an .itp file, for GROMACS. The documentation points to external tools such as the ATB Server or CGenFF as possible ways to generate these files. They can then be supplied during the GROMACS Wizard preparation step. In other words, retaining a molecule is a modeling decision that can have a follow-up preparation task.
Once cleanup is complete, continue to Step 1: Prepare to define the simulation model, box, solvent, ions, and project files. For the full walkthrough and additional guidance, see the GROMACS Wizard pre-processing tutorial.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.
