Before equilibration: read the signals in your energy-minimization results

A minimization run can finish and still leave you wondering: is this structure ready for equilibration, or did the calculation simply stop? That uncertainty matters. Moving forward with a system that still has large forces can make the next stage harder to interpret. A useful check is to consider the energy plot and the reported maximum force together—not just whether the job completed.

Energy minimization is a way to relax steric clashes and poor local geometry before equilibration. In SAMSON’s GROMACS Wizard, the workflow starts from a prepared GRO file or a prepared batch project. If you are continuing from the previous step, the auto-fill button can populate the input path from the prior successful run. You can also choose the GRO file yourself.

What the plot can—and cannot—tell you

The potential-energy plot, Epot, shows how the system’s potential energy changes over minimization steps. A steady downward trend and convergence, like the example below, are encouraging signs that the minimization is progressing smoothly.

Example potential-energy plot during energy minimization

But a visually reassuring plot is not the whole decision. Check the output for both the potential energy and the maximum force, Fmax. The plot describes the evolution of energy; the force tells you whether the minimization reached the target set by the energy-minimization tolerance, emtol.

Use two checks before moving on

  • Potential energy: Epot should be negative. For a simple protein in water, its magnitude may be on the order of 105–106, depending on system size and the number of water molecules. Treat this as a broad reference, not a universal pass/fail value.
  • Maximum force: compare Fmax with the target set in the advanced parameters. For example, emtol = 1000.0 corresponds to a target maximum force no greater than 1000 kJ mol-1 nm-1.

The output window is where you can check these values per step and at the end of the run. The example below shows the kind of output to inspect.

Energy-minimization output with values to review

When the run stops but the force is still too high

A minimization can reach its maximum number of steps with a reasonable-looking Epot while still having Fmax > emtol. In that situation, do not treat completion alone as proof that the system is ready for equilibration. The system may not yet be stable enough for the next stage.

Instead, use the results to decide what to investigate. The documented options include increasing the number of minimization steps, running minimization again using the previous minimization output as input, decreasing the minimization step size, or changing minimization parameters such as the integrator. These are choices to evaluate for your system—not automatic fixes. Advanced parameters can be reviewed in the Minimize tab, and the tooltips provide parameter details.

A practical review sequence

  1. Confirm that the job completed and locate its output in the Output window or Local jobs.
  2. Review the Epot plot for the overall energy trend and convergence.
  3. Read the final Epot and Fmax values in the output.
  4. Compare Fmax with the selected emtol, rather than relying on the plot alone.
  5. Continue to NVT equilibration only when the energy and force are acceptable for your system.

Plots are generated when the job finishes and results are loaded, including for each subproject in a batch. You can save a plot using the Save button. Results are kept in the specified results folder; energy-minimization folders have the suffix _em. Importing the trajectory is optional: cancelling the import does not delete the results, and the plot is still generated.

For the complete workflow and interface details, read the Energy Minimization tutorial.

Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.

Comments are closed.