The 0.105 nm setting that can trip up coarse-grained solvation

Preparing a coarse-grained (CG) model for molecular dynamics can look deceptively familiar: load the structure, add solvent, add ions, and continue to minimization. But one small default can matter. When GROMACS does not have van der Waals distances defined for a CG model, it uses a default distance of 0.105 nm. For MARTINI water beads, that can be too close: each bead represents four water molecules.

The result is a preparation step that deserves a quick check before you launch a simulation. In GROMACS Wizard, increasing the default van der Waals distance to, for example, 0.21 nm helps avoid clashes and supports proper solvent density. The value is a practical setting from the tutorial, not a universal guarantee for every CG force field, so check that your model and solvent are appropriate.

Start with the files that belong together

Before opening the preparation workflow, make sure you have a valid CG model. If it came from Martinize2, keep the generated structure and topology files together in the same output folder. In GROMACS Wizard, choose Prepare, set the system source to Folder, and select that folder. The wizard detects available PDB, TOP, and ITP files.

Load the detected PDB file. This loads the structure into a document and computes a periodic box for it. If the model was generated with Martinize2 for MARTINI 3.0.0, verify that the force field is set to martini_v.3.0.0 and that the default Martini water model is selected. If your model uses a different CG force field, provide the appropriate custom force field rather than assuming the MARTINI setting is suitable.

Detected coarse-grained input files

Set solvent options deliberately

If the system needs solvent, enable Add solvent and open its options. Increase the default van der Waals distance; the tutorial gives 0.21 nm as an example. The reason is specific to CG models: the default 0.105 nm may be too small for CG beads, while a MARTINI water bead represents four water molecules. Other solvent options can remain at their defaults for the example workflow.

Solvent options, including the van der Waals distance

Next, review the periodic box. You can adjust the solute-to-box distance if needed; the tutorial recommends at least 1 nm to maintain the minimum distance between periodic images. A rhombic dodecahedron is another option: it is a compact, regular space-filling unit cell.

Add ions only when solvent is enabled

Choose positive and negative ions to neutralize the system, and set additional salt concentration if that is part of your setup. There is an important dependency: GROMACS Wizard adds ions by replacing solvent molecules, so you must enable solvent before asking it to neutralize the system or add ions. If ion options are unavailable or do not behave as expected, check this first.

Salt concentration options for adding ions

Prepare, inspect, then continue

Click Prepare. You can load and inspect the prepared structure, or move on to minimization. A useful pre-run check is to confirm that the input files were detected, the intended force field is selected, the solvent distance was reviewed, the box size is suitable, and ions are requested only when solvent is enabled.

For the next stage, switch to Minimize and use the auto-fill button to set the previous preparation result as the input structure. GROMACS Wizard can also detect position-restraint definitions from the topology files. In Martinize2-generated files, restraint records may be separated by molecule; for example, POSRES_MOLECULE_0 corresponds to molecule 0. Check which restraints exist and whether they are appropriate for minimization or equilibration.

For the complete workflow and screenshots, see the GROMACS Wizard guide to coarse-grained systems.

Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON at https://www.samson-connect.net.

Comments are closed.