A coarse-grained system can look ready for simulation and still run into trouble as soon as solvent is added. One easily missed detail is the distance GROMACS uses to keep solvent beads away from the solute. For coarse-grained models, the default may be too small: a Martini water bead represents four water molecules, so treating it like an atomistic water molecule can place solvent beads uncomfortably close to the system.
The GROMACS Wizard tutorial highlights a practical adjustment: when setting up solvent for a coarse-grained system, increase the default van der Waals distance from 0.105 nm to, for example, 0.21 nm. This is useful to check before preparing the system, because GROMACS does not have van der Waals distances defined for coarse-grained models in this situation and uses its default value.
A preparation workflow that catches common oversights
Start with a valid coarse-grained model and keep its structure and topology files together. For a model generated with Martinize2, select the output folder containing files such as *_CG.pdb and *_CG.top, along with the associated topology files. In GROMACS Wizard, open the Prepare tab, set the input source to Folder, and choose that folder.
After the files are detected, load the PDB file. This loads the structure into a new document and computes a periodic box. If the model was generated with Martinize2 for MARTINI v.3.0.0, check that the force field is set to martini_v.3.0.0 and that the solvent model is the default Martini water. If you use a different coarse-grained force field, provide the appropriate custom force field instead.

Set solvent distance before preparing
If you want to solvate the system, enable Add solvent and open its options. Increase the default van der Waals distance to a value such as 0.21 nm; the tutorial explains that the default 0.105 nm may be too close for coarse-grained beads. Other solvent options can remain at their defaults. A custom coarse-grained solvent model is also possible when your workflow requires one.

Next, review the periodic box. Change its size if needed, and keep the solute-to-box distance at least 1 nm to ensure the minimum distance between periodic images. You can also choose a rhombic dodecahedron, which the tutorial identifies as the smallest and most regular space-filling unit cell.
Remember the solvent–ion dependency
To neutralize the system or add extra ions, enable solvent first. GROMACS Wizard adds ions by replacing solvent molecules, so the ion step depends on solvent being present. Choose positive and negative ions for neutralization; if adding salt, select the salt-concentration option and specify its parameters.
Once these choices are checked, click Prepare. You can load and inspect the prepared structure, including the periodic box and detected index groups, or continue to minimization. SAMSON can display coarse-grained systems as connected beads and colorize water and ion beads, which can help with a visual check of the prepared system.
For the next stage, use the Minimize tab and its auto-fill button to use the previous preparation result as the input structure. If your topology contains position-restraint definitions, review the options in advanced parameters: GROMACS Wizard fills them based on the topology, and restraints can be applied during minimization and equilibration.
The key checks before moving on are simple: confirm the intended force field, increase the coarse-grained solvent distance when solvating, review the box spacing, and enable solvent before adding ions. See the original coarse-grained systems tutorial for the complete workflow and related simulation steps.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.
