The Small Solvent Setting That Can Trip Up a Coarse-Grained Simulation

Preparing a coarse-grained (CG) model for molecular dynamics can feel deceptively familiar: load the structure, add water, and prepare the simulation. But a setting that works for an atomistic system may place coarse-grained solvent beads too close to the model. That can lead to clashes or an unsuitable solvent arrangement before the simulation even begins.

The reason is a difference in what the particles represent. In the MARTINI model described here, each water bead represents four water molecules. GROMACS does not have van der Waals distances defined for every CG model, so it may use its default distance of 0.105 nm. For CG beads, that default can be too small. The GROMACS Wizard tutorial recommends increasing the van der Waals distance when adding solvent—for example, to 0.21 nm.

Solvent options for a coarse-grained system
When adding solvent to a CG system, review the solvent options and increase the default van der Waals distance as appropriate.

A practical preparation workflow

Start with a valid CG model and keep its structure and topology files together. If the model was generated with Martinize2, select the output folder containing files such as *_CG.pdb and *_CG.top, along with the relevant topology include files. In GROMACS Wizard, open the Prepare tab, set the system source to Folder, and select that folder.

Check the detected PDB, TOP, and ITP files before proceeding. Load the PDB using the adjacent Load button: this loads the system into a document and computes a periodic box. For a MARTINI v.3.0.0 system made with Martinize2, verify that the force field is set to martini_v.3.0.0 and that the expected Martini water model is selected. If your CG model uses another force field, provide the matching custom force field rather than assuming the MARTINI setting applies.

Solvent, box, and ions: settings that depend on each other

If you need solvent, enable Add solvent and open its options. Increase the default van der Waals distance—0.21 nm is an example given in the tutorial—then leave the other options at their defaults unless your setup calls for a change. The point is not that one value fits every CG model; it is to avoid blindly carrying over a distance that may be too small for the beads in your system.

Next, review the periodic box. You can adjust the solute-to-box distance or choose a different unit-cell shape, such as a rhombic dodecahedron. The tutorial notes that the solute-box distance should be at least 1 nm to ensure the minimum distance between periodic images. Treat this as a preparation check, not as a substitute for considering the needs of your particular simulation.

Plan ion addition alongside solvation. You can neutralize the system and, if desired, add extra ions using a salt-concentration option. However, GROMACS Wizard adds ions by replacing solvent molecules, so the option to add solvent must be enabled if you want to neutralize the system or add ions.

Coarse-grained system with a computed periodic box
Loading the structure computes a periodic box that you can review during preparation.

Verify before moving on

Once you click Prepare, you can load and inspect the prepared structure before beginning molecular dynamics. SAMSON can detect CG systems and display them as connected beads; water appears blue, and ion beads are colored using CPK colors for their corresponding atoms. These visual cues help you recognize components in the prepared system, while the detected input files and settings provide a useful checklist for confirming that the intended model was used.

When the preparation looks right, continue to the Minimize tab and use the auto-fill button to set the previous step’s results as the input structure. Advanced parameters include position restraints, which may be populated from POSRES* defines in the topology. If Martinize2 generated restraints, its per-molecule records are numbered from 0; if restraints were disabled there, none will be present. Check which restraint definitions exist before relying on them for minimization or equilibration.

This sequence—confirm files and force field, adjust CG solvent distance, review the box, and enable solvent when adding ions—helps catch common preparation mismatches before they become simulation problems. For the full walkthrough and screenshots, learn more in the GROMACS Wizard coarse-grained systems tutorial.

Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.

Comments are closed.