Molecular modeling and simulations often involve the intricate task of studying inter-molecular behavior under specific forces. One such technique is center-of-mass (COM) pulling, a valuable tool when dissecting the interactions between distinct molecular chains. In this blog post, we’ll explore how to set up and run a COM pulling simulation using the powerful GROMACS Wizard extension in SAMSON.
Why Center-of-Mass Pulling?
COM pulling allows researchers to simulate and measure forces required to separate molecular chains or other complex systems. This is indispensable when investigating protein-ligand interactions, studying membrane mechanics, or quantifying conformational changes.
Getting Started: Key Steps
With GROMACS Wizard in SAMSON, setting up COM pulling becomes a simplified, step-by-step process. Let’s break down the essential elements—loading the system, preparing the molecular setup, and configuring parameters for seamless results.
Loading the Molecular System in SAMSON
- Navigate to Home > Fetch in SAMSON.
- Input “2BEG” (for this tutorial) under the PDB or PDB (mmCIF) fields and load the structural model.
- Once loaded, observe the 2BEG system in the Document View. SAMSON’s interactive interface lets you identify and manipulate chains within the structure.
Here’s an example of the system represented in the viewport:

Setting Up the Simulation Box
A key requirement in COM pulling is ensuring adequate space in the pulling direction. For a successful pulling simulation:
- Choose an Orthorhombic unit cell and compute a fitted box around the system.
- Adjust box dimensions to accommodate the pull. In this tutorial, pulling occurs along the z-axis by 5 nm, requiring a box length of at least 12 nm in the z-direction.
- Deactivate the Center in box option and adjust the box center to specific coordinates such as
0.5 x 0.5 x 0.2.
Here’s a visualization of the box setup:

Neutralizing and Solvating the Molecular System
To ensure a realistic biophysical environment, it’s essential to neutralize the system and add a saline concentration:
- Activate the Neutralize system option to counter system charge using Na and Cl ions.
- Add a salt concentration of 100 mM (0.1 mol/liter) to mimic a physiological environment.

Defining COM Pulling Parameters
The most critical part of this setup involves specifying how chain A will be pulled from chain B:
- Under “COM Pulling,” create a new pull coordinate.
- Specify Chain A and Chain B as the groups for pulling.
- Define the pulling parameters such as:
- Type: umbrella
- Geometry: distance
- Direction: pulling along z-axis
- Rate: 0.01 nm/ps (for a 5 nm pull in 0.5 ns).
The COM pulling section will look like this:

Running and Analyzing the Simulation
Once the setup is complete, initiate COM pulling either locally or using the cloud option. The GROMACS Wizard also enables tracking force and displacement plots during the simulation:

The generated plots give insight into force buildup and displacement over time, allowing researchers to interpret molecular resilience and interaction forces.
Final Thoughts
COM pulling techniques offer an intuitive way to explore molecular behaviors under controlled forces, providing essential insights for structural biology and biophysics. With the GROMACS Wizard in SAMSON, setting up and visualizing such simulations is remarkably convenient for any molecular modeler.
To dive deeper into the steps or explore advanced capabilities, visit the original tutorial and streamline your simulation process today!
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get started with SAMSON at SAMSON Connect.
