A molecular dynamics run can finish successfully and still leave you wondering: is the system actually ready for the next step? During NVT equilibration, the key question is whether the temperature has settled around its target—not whether every point on the plot is perfectly flat. Knowing what to check can help you avoid moving on too early or rerunning a step without a clear reason.
NVT keeps the number of particles, volume, and temperature constant. In the GROMACS Wizard workflow, this is the first equilibration phase after energy minimization. Its purpose is to bring the system to the target temperature in a controlled way. Density is addressed in the following NPT equilibration step, so a stable NVT temperature does not mean the whole equilibration process is complete.
Start with a suitable input
Use the GRO file produced by minimization or by a previous NVT run, or provide a minimized batch project. If you are continuing from the previous Wizard step, the auto-fill button can populate the input path from the previous successful run. This is especially useful when you need to extend equilibration: start from the latest NVT results rather than returning to the original minimized structure.

Choose parameters with the goal in mind
The NVT tab provides commonly adjusted settings such as the integration time step and number of steps, while additional GROMACS parameters are available through the advanced settings. The defaults are intended for typical runs, but they should not be treated as a guarantee that every system will equilibrate in the same amount of time.
For many projects, the temperature-coupling example uses velocity rescaling with a stochastic term (v-rescale), with a time constant of about 1 ps. Check that the temperature used for velocity generation corresponds to the coupling reference temperature. If you use multiple coupling groups—for example, Protein and non-Protein—make sure the time constants and reference temperatures match the number of groups. Position-restraint options are filled automatically based on the input system.

For the tutorial, the parameters are reset to their defaults. In your own work, use custom settings only when you have a reason to do so, and keep track of changes. The advanced-parameter window lets you reset values, load them from an MDP file, or save them to one.
Read the plot, not just the job status
A completed job tells you the calculation ended; the temperature plot helps you judge whether the system is ready to proceed. Look for the running average to reach a plateau around the target value. Small fluctuations are normal. The example in the tutorial stabilizes around 300 K, the default reference temperature shown there.

Typical NVT equilibration may take about 50–100 ps, but the time depends on the size and contents of the system. If the temperature has not reached the target or still appears to be settling, additional time may be needed. You can run NVT again using the current NVT output as the input. If the plot looks stable enough for your workflow, continue to NPT to work toward the desired density.
Keep the results easy to inspect
After a local run, use the results-import options to load the full trajectory, the last frame, or a selected range of frames. You can also choose periodic-boundary-condition treatment and what to center the system on. If you cancel the import, the results are not deleted, and the plot can still be generated. Results are stored in the specified results folder; NVT run folders use the suffix _nvt.
The useful habit is simple: treat the temperature trace as a checkpoint, not a decoration. Confirm that it is fluctuating around the target and looks stable enough before proceeding. For the complete walkthrough, see the NVT Equilibration documentation.
Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.