The Small Distance Setting That Can Make or Break Coarse-Grained Solvation

Preparing a coarse-grained (CG) system for molecular dynamics can look straightforward: load the structure, add water, and continue to simulation. But there is an easy-to-miss detail in that sequence. A default solvent distance that works for an atomistic model may be too small for coarse-grained beads, potentially placing solvent too close to the solute. Getting this setting right before preparation can help you avoid an unnecessarily crowded starting structure.

This walkthrough focuses on that practical issue while covering the surrounding setup: loading a CG model, checking its force field, choosing box settings, and adding ions. The example is a MARTINI v.3.0.0 system generated with Martinize2, prepared in SAMSON’s GROMACS Wizard.

Start with a complete input folder

Before opening GROMACS Wizard, make sure you have a valid CG model and keep its structure and topology files together. In the Wizard’s Prepare tab, set the system source to Folder, browse to the folder, and check that the expected files are detected. For a Martinize2 model, the output folder should contain files such as *_CG.pdb and *_CG.top, along with any relevant topology include files.

Load the detected PDB file. This loads the system into a document and computes a periodic box, giving you a structure to inspect before proceeding.

Structure and topology files detected in the input folder
Check that the expected structure and topology files are detected before preparing the system.

Check the force field before adding solvent

For a model generated with Martinize2 for MARTINI v.3.0.0, GROMACS Wizard should switch to the bundled martini_v.3.0.0 force field and select the default Martini water model. Confirm that the force field shown is the one you intend to use. If your CG model uses another force field, the corresponding custom force field must be provided rather than assuming the MARTINI setting is appropriate.

Why the default solvent distance needs attention

If you want to solvate the system, enable Add solvent and open its options. Increase the default van der Waals distance to, for example, 0.21 nm.

The reason is specific to this CG workflow: GROMACS does not have van der Waals distances defined for CG models, so it uses a default value of 0.105 nm. That distance may be too small for Martini beads, because each Martini water bead represents four water molecules. Increasing the distance helps avoid clashes and supports an appropriate solvent density. The tutorial recommends leaving the other solvent options at their defaults unless your setup calls for a custom solvent model.

Solvent options for the coarse-grained system
Increase the default van der Waals distance in the solvent options; 0.21 nm is given as an example.

Set the box and ions in the right order

Review the periodic box before preparation. You can adjust the solute-to-box distance; the documentation recommends at least 1 nm to ensure the minimum distance between periodic images. You can also choose a rhombic dodecahedron, a space-filling unit cell that is smaller and more regular than a cubic box.

To neutralize the system or add salt, enable solvent first. GROMACS adds ions by replacing solvent molecules, so the solvent option is required for ion addition. Choose the positive and negative ions, then set additional salt-concentration parameters if needed. This order matters: ion settings alone are not enough if solvent has not been enabled.

Prepare, inspect, then continue

Once the input files, force field, solvent distance, box, and ion settings are ready, click Prepare. You can load and inspect the prepared structure, or continue directly to minimization. When you move to the Minimize tab, use the auto-fill button to set the previous preparation results as the input structure.

One further check is useful if your topology includes position restraints. In the advanced parameters, GROMACS Wizard detects restraint options from the topology’s POSRES* defines. Martinize2 may generate separate restraint records for each molecule, or none at all, depending on the option selected when the model was created. Confirm that the restraints shown match your intended workflow before applying them during minimization or equilibration.

The main practical lesson: for CG solvation, don’t assume the default atomistic-scale distance is suitable. Confirm the force field and deliberately review the solvent distance before preparing the system. For the complete walkthrough, see the GROMACS Wizard coarse-grained systems tutorial.

Note: SAMSON and all SAMSON Extensions are free for non-commercial use. Get SAMSON.

Comments are closed.